Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 96(11): 4455-4462, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38458998

RESUMO

The functions of proteins bearing multiple post-translational modifications (PTMs) are modulated by their modification patterns, yet precise characterization of them is difficult. MEK1 (also known as MAP2K1) is one such example that acts as a gatekeeper of the mitogen-activating protein kinase (MAPK) pathway and propagates signals via phosphorylation by upstream kinases. In principle, top-down mass spectrometry can precisely characterize whole MEK1 proteoforms, but fragmentation methods that would enable the site-specific characterization of labile modifications on 43 kDa protein ions result in overly dense tandem mass spectra. By using the charge-detection method called individual ion mass spectrometry, we demonstrate how complex mixtures of phosphoproteoforms and their fragment ions can be reproducibly handled to provide a "bird's eye" view of signaling activity through mapping proteoform landscapes in a pathway. Using this approach, the overall stoichiometry and distribution of 0-4 phosphorylations on MEK1 was determined in a cellular model of drug-resistant metastatic melanoma. This approach can be generalized to other multiply modified proteoforms, for which PTM combinations are key to their function and drug action.


Assuntos
Mitógenos , Proteínas Quinases , Espectrometria de Massas em Tandem/métodos , Processamento de Proteína Pós-Traducional , Peptídeos e Proteínas de Sinalização Intercelular , Íons
2.
J Proteome Res ; 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38497708

RESUMO

We introduce single cell Proteoform imaging Mass Spectrometry (scPiMS), which realizes the benefit of direct solvent extraction and MS detection of intact proteins from single cells dropcast onto glass slides. Sampling and detection of whole proteoforms by individual ion mass spectrometry enable a scalable approach to single cell proteomics. This new scPiMS platform addresses the throughput bottleneck in single cell proteomics and boosts the cell processing rate by several fold while accessing protein composition with higher coverage.

3.
J Am Soc Mass Spectrom ; 35(4): 658-662, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38286823

RESUMO

The quality of data in charge detection mass spectrometry depends on accurate determination of ion charge. While the method of selective temporal overview of resonant ions (STORI) has proven to be highly enabling for determining the charge of ions that survive for variable amounts of time, it assumes that the ion frequency exactly matches the frequency being used in the calculation. Any mismatches result in low charge estimates. To address this, the misSTORI method was developed to correct these discrepancies. This can significantly reduce the charge measurement errors for samples with unstable masses. As an example, the misSTORI approach can eliminate a 5.7% charge determination error for a VP3-only AAV capsid that shifts 25 ppm in mass.

4.
J Am Soc Mass Spectrom ; 35(1): 62-73, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38032172

RESUMO

Surface-embedded glycoproteins, such as the spike protein trimers of coronaviruses MERS, SARS-CoV, and SARS-CoV-2, play a key role in viral function and are the target antigen for many vaccines. However, their significant glycan heterogeneity poses an analytical challenge. Here, we utilized individual ion mass spectrometry (I2MS), a multiplexed charge detection measurement with similarities to charge detection mass spectrometry (CDMS), in which a commercially available Orbitrap analyzer is used to directly produce mass profiles of these heterogeneous coronavirus spike protein trimers under native-like conditions. Analysis by I2MS shows that glycosylation contributes to the molecular mass of each protein trimer more significantly than expected by bottom-up techniques, highlighting the importance of obtaining complementary intact mass information when characterizing glycosylation of such heterogeneous proteins. Enzymatic dissection to remove sialic acid or N-linked glycans demonstrates that I2MS can be used to better understand the glycan profile from a native viewpoint. Deglycosylation of N-glycans followed by I2MS analysis indicates that the SARS-CoV-2 spike protein trimer contains glycans that are more difficult to remove than its MERS and SARS-CoV counterparts, and these differences are correlated with solvent accessibility. I2MS technology enables characterization of protein mass and intact glycan profile and is orthogonal to traditional mass analysis methods such as size exclusion chromatography-multiangle light scattering (SEC-MALS) and field flow fractionation-multiangle light scattering (FFF-MALS). An added advantage of I2MS is low sample use, requiring 100-fold less than other methodologies. This work highlights how I2MS technology can enable efficient development of vaccines and therapeutics for pharmaceutical development.


Assuntos
Glicoproteína da Espícula de Coronavírus , Vacinas , Humanos , Glicoproteína da Espícula de Coronavírus/química , Espectrometria de Massas/métodos , Polissacarídeos/análise
6.
J Am Soc Mass Spectrom ; 34(12): 2625-2629, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38011219

RESUMO

Collision cross section (CCS) measurements determined by ion mobility spectrometry (IMS) provide useful information about gas-phase protein structure that is complementary to mass analysis. Methods for determining CCS without a dedicated IMS system have been developed for Fourier transform mass spectrometry (FT-MS) platforms by measuring the signal decay during detection. Individual ion mass spectrometry (I2MS) provides charge detection and measures ion lifetimes across the length of an FT-MS detection event. By tracking lifetimes for entire ion populations, we demonstrate simultaneous determination of charge, mass, and CCS for proteins and complexes ranging from ∼8 to ∼232 kDa.


Assuntos
Espectrometria de Mobilidade Iônica , Proteínas , Espectrometria de Massas/métodos , Proteínas/química , Espectrometria de Mobilidade Iônica/métodos
7.
Nat Commun ; 14(1): 6478, 2023 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-37838706

RESUMO

The molecular identification of tissue proteoforms by top-down mass spectrometry (TDMS) is significantly limited by throughput and dynamic range. We introduce AutoPiMS, a single-ion MS based multiplexed workflow for top-down tandem MS (MS2) directly from tissue microenvironments in a semi-automated manner. AutoPiMS directly off human ovarian cancer sections allowed for MS2 identification of 73 proteoforms up to 54 kDa at a rate of <1 min per proteoform. AutoPiMS is directly interfaced with multifaceted proteoform imaging MS data modalities for the identification of proteoform signatures in tumor and stromal regions in ovarian cancer biopsies. From a total of ~1000 proteoforms detected by region-of-interest label-free quantitation, we discover 303 differential proteoforms in stroma versus tumor from the same patient. 14 of the top proteoform signatures are corroborated by MSI at 20 micron resolution including the differential localization of methylated forms of CRIP1, indicating the importance of proteoform-enabled spatial biology in ovarian cancer.


Assuntos
Neoplasias Ovarianas , Proteoma , Humanos , Feminino , Proteoma/análise , Neoplasias Ovarianas/diagnóstico por imagem , Espectrometria de Massas em Tandem/métodos , Software , Microambiente Tumoral
8.
J Am Soc Mass Spectrom ; 34(10): 2093-2097, 2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37683262

RESUMO

Antibody-antigen interactions are central to the immune response. Variation of protein antigens such as isoforms and post-translational modifications can alter their antibody binding sites. To directly connect the recognition of protein antigens with their molecular composition, we probed antibody-antigen complexes by using native tandem mass spectrometry. Specifically, we characterized the prominent peanut allergen Ara h 2 and a convergent IgE variable region discovered in patients who are allergic to peanuts. In addition to measuring the antigen-induced dimerization of IgE antibodies, we demonstrated how immunocomplexes can be isolated in the gas phase and activated to eject, identify, and characterize proteoforms of their bound antigens. Using tandem experiments, we isolated the ejected antigens and then fragmented them to identify their chemical composition. These results establish native top-down mass spectrometry as a viable platform for precise and thorough characterization of immunocomplexes to relate structure to function and enable the discovery of antigen proteoforms and their binding sites.


Assuntos
Alérgenos , Espectrometria de Massas em Tandem , Humanos , Isoformas de Proteínas , Imunoglobulina E/metabolismo , Antígenos de Plantas/metabolismo
9.
Anal Chem ; 95(37): 13889-13896, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37672632

RESUMO

Charge detection mass spectrometry (CDMS) enables the direct mass measurement of heterogeneous samples on the megadalton scale, as the charge state for a single ion is determined simultaneously with the mass-to-charge ratio (m/z). Surface-induced dissociation (SID) is an effective activation method to dissociate non-intertwined, non-covalent protein complexes without extensive gas-phase restructuring, producing various subcomplexes reflective of the native protein topology. Here, we demonstrate that using CDMS after SID on an Orbitrap platform offers subunit connectivity, topology, proteoform information, and relative interfacial strengths of the intact macromolecular assemblies. SID dissects the capsids (∼3.7 MDa) of adeno-associated viruses (AAVs) into trimer-containing fragments (3mer, 6mer, 9mer, 15mer, etc.) that can be detected by the individual ion mass spectrometry (I2MS) approach on Orbitrap instruments. SID coupled to CDMS provides unique structural insights into heterogeneous assemblies that are not readily obtained by traditional MS measurements.


Assuntos
Capsídeo , Dependovirus , Espectrometria de Massas , Software
10.
J Phys Chem A ; 127(32): 6749-6763, 2023 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-37531463

RESUMO

Beyond the now well-known strong catalyst-support interactions reported for ceria-supported platinum catalysts, intermetallic Ce-Pt compounds exhibit fascinating properties such as heavy fermion behavior and magnetic instability. Small heterometallic Ce-Pt clusters, which can provide insights into the local features that govern bulk phenomena, have been less explored. Herein, the anion photoelectron spectra of three small mixed Ce-Pt clusters, Ce2OPt-, Ce2Pt-, and Ce3Pt-, are presented and interpreted with supporting density functional theory calculations. The calculations, which are readily reconciled with the experimental spectra, suggest the presence of numerous close-lying spin states, including states in which the Ce 4f electrons are ferromagnetically coupled or antiferromagnetically coupled. The Pt center is consistently in a nominal -2 charge state in all cluster neutrals and anions, giving the Ce-Pt bond ionic character. Ce-Pt bonds are stronger than Ce-Ce bonds, and the O atom in Ce2OPt- coordinates only with the Ce centers. The energy of the singly occupied Ce-local 4f orbitals relative to the Pt-local orbitals changes with cluster composition. Discussion of the results includes potential implications for Ce-rich intermetallic materials.

11.
Anal Chem ; 94(48): 16543-16548, 2022 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-36416365

RESUMO

Charge detection mass spectrometry (CDMS) provides mass domain spectra of large and highly heterogeneous analytes. Over the past few years, we have multiplexed CDMS on Orbitrap instruments, an approach termed Individual Ion Mass Spectrometry (I2MS). Until now, I2MS required manual adjustment of injection times to collect spectra in the individual ion regime. To increase sample adaptability, enable online separations, and reduce the barrier for entry, we report an automated method for adjusting ion injection times in I2MS for image current detectors like the Orbitrap. Automatic Ion Control (AIC) utilizes the density of signals in the m/z domain to adjust an ensemble of ions down to the individual ion regime in real-time. The AIC technique was applied to both denatured and native proteins yielding high quality data without human intervention directly in the mass domain.


Assuntos
Proteínas , Humanos , Espectrometria de Massas/métodos , Íons/química , Proteínas/análise
12.
J Proteome Res ; 21(12): 2987-2997, 2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36343328

RESUMO

SARS-CoV-2 Omicron (B.1.1.529) and its subvariants are currently the most common variants of concern worldwide, featuring numerous mutations in the spike protein and elsewhere that collectively make Omicron variants more transmissible and more resistant to antibody-mediated neutralization provided by vaccination, previous infections, and monoclonal antibody therapies than their predecessors. We recently reported the creation and characterization of Ig-MS, a new mass spectrometry-based serology platform that can define the repertoire of antibodies against an antigen of interest at single proteoform resolution. Here, we applied Ig-MS to investigate the evolution of plasma antibody repertoires against the receptor-binding domain (RBD) of SARS-CoV-2 in response to the booster shot and natural viral infection. We also assessed the capacity for antibody repertoires generated in response to vaccination and/or infection with the Omicron variant to bind to both Wuhan- and Omicron-RBDs. Our results show that (1) the booster increases antibody titers against both Wuhan- and Omicron- RBDs and elicits an Omicron-specific response and (2) vaccination and infection act synergistically in generating anti-RBD antibody repertoires able to bind both Wuhan- and Omicron-RBDs with variant-specific antibodies.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Anticorpos , Imunoterapia , Anticorpos Antivirais
13.
Sci Adv ; 8(32): eabp9929, 2022 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-35947651

RESUMO

Imaging of proteoforms in human tissues is hindered by low molecular specificity and limited proteome coverage. Here, we introduce proteoform imaging mass spectrometry (PiMS), which increases the size limit for proteoform detection and identification by fourfold compared to reported methods and reveals tissue localization of proteoforms at <80-µm spatial resolution. PiMS advances proteoform imaging by combining ambient nanospray desorption electrospray ionization with ion detection using individual ion mass spectrometry. We demonstrate highly multiplexed proteoform imaging of human kidney, annotating 169 of 400 proteoforms of <70 kDa using top-down MS and a database lookup of ~1000 kidney candidate proteoforms, including dozens of key enzymes in primary metabolism. PiMS images reveal distinct spatial localizations of proteoforms to both anatomical structures and cellular neighborhoods in the vasculature, medulla, and cortex regions of the human kidney. The benefits of PiMS are poised to increase proteome coverage for label-free protein imaging of tissues.

14.
J Proteome Res ; 21(1): 274-288, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34878788

RESUMO

Methods of antibody detection are used to assess exposure or immunity to a pathogen. Here, we present Ig-MS, a novel serological readout that captures the immunoglobulin (Ig) repertoire at molecular resolution, including entire variable regions in Ig light and heavy chains. Ig-MS uses recent advances in protein mass spectrometry (MS) for multiparametric readout of antibodies, with new metrics like Ion Titer (IT) and Degree of Clonality (DoC) capturing the heterogeneity and relative abundance of individual clones without sequencing of B cells. We applied Ig-MS to plasma from subjects with severe and mild COVID-19 and immunized subjects after two vaccine doses, using the receptor-binding domain (RBD) of the spike protein of SARS-CoV-2 as the bait for antibody capture. Importantly, we report a new data type for human serology, that could use other antigens of interest to gauge immune responses to vaccination, pathogens, or autoimmune disorders.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Neutralizantes , Anticorpos Antivirais , Humanos , Espectrometria de Massas , Glicoproteína da Espícula de Coronavírus/genética
15.
medRxiv ; 2021 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-34268518

RESUMO

Methods of antibody detection are used to assess exposure or immunity to a pathogen. Here, we present Ig-MS , a novel serological readout that captures the immunoglobulin (Ig) repertoire at molecular resolution, including entire variable regions in Ig light and heavy chains. Ig-MS uses recent advances in protein mass spectrometry (MS) for multi-parametric readout of antibodies, with new metrics like Ion Titer (IT) and Degree of Clonality (DoC) capturing the heterogeneity and relative abundance of individual clones without sequencing of B cells. We apply Ig-MS to plasma from subjects with severe & mild COVID-19, using the receptor-binding domain (RBD) of the spike protein of SARS-CoV-2 as the bait for antibody capture. Importantly, we report a new data type for human serology, with compatibility to any recombinant antigen to gauge our immune responses to vaccination, pathogens, or autoimmune disorders.

16.
Nat Methods ; 18(3): 303-308, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33589837

RESUMO

Current proteomic approaches disassemble and digest nucleosome particles, blurring readouts of the 'histone code'. To preserve nucleosome-level information, we developed Nuc-MS, which displays the landscape of histone variants and their post-translational modifications (PTMs) in a single mass spectrum. Combined with immunoprecipitation, Nuc-MS quantified nucleosome co-occupancy of histone H3.3 with variant H2A.Z (sixfold over bulk) and the co-occurrence of oncogenic H3.3K27M with euchromatic marks (for example, a >15-fold enrichment of dimethylated H3K79me2). Nuc-MS is highly concordant with chromatin immunoprecipitation-sequencing (ChIP-seq) and offers a new readout of nucleosome-level biology.


Assuntos
Histonas/metabolismo , Nucleossomos/metabolismo , Proteômica/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Linhagem Celular , Imunoprecipitação da Cromatina/métodos , Células HEK293 , Código das Histonas , Humanos , Metilação
17.
Anal Chem ; 93(5): 2723-2727, 2021 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-33322893

RESUMO

Native mass spectrometry involves transferring large biomolecular complexes into the gas phase, enabling the characterization of their composition and stoichiometry. However, the overlap in distributions created by residual solvation, ionic adducts, and post-translational modifications creates a high degree of complexity that typically goes unresolved at masses above ∼150 kDa. Therefore, native mass spectrometry would greatly benefit from higher resolution approaches for intact proteins and their complexes. By recording mass spectra of individual ions via charge detection mass spectrometry, we report isotopic resolution for pyruvate kinase (232 kDa) and ß-galactosidase (466 kDa), extending the limits of isotopic resolution for high mass and high m/z by >2.5-fold and >1.6-fold, respectively.


Assuntos
Processamento de Proteína Pós-Traducional , Proteínas , Íons , Espectrometria de Massas
18.
Nat Methods ; 17(4): 391-394, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32123391

RESUMO

An Orbitrap-based ion analysis procedure determines the direct charge for numerous individual protein ions to generate true mass spectra. This individual ion mass spectrometry (I2MS) method for charge detection enables the characterization of highly complicated mixtures of proteoforms and their complexes in both denatured and native modes of operation, revealing information not obtainable by typical measurements of ensembles of ions.


Assuntos
Espectrometria de Massas/métodos , Proteínas/química , Proteômica/métodos , Humanos
19.
J Proteome Res ; 19(3): 1346-1350, 2020 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-32032494

RESUMO

Charge detection mass spectrometry (CDMS) is mainly utilized to determine the mass of intact molecules. Previous applications of CDMS have determined the mass-to-charge ratio and the charge of large polymers, DNA molecules, and native protein complexes, from which corresponding mass values could be assigned. Recent advances have demonstrated that CDMS using an Orbitrap mass analyzer yields the reliable assignment of integer charge states that enables individual ion mass spectrometry (I2MS) and spectral output directly into the mass domain. Here I2MS analysis was extended to isotopically resolved fragment ions from intact proteoforms for the first time. With a radically different bias for ion readout, I2MS identified low-abundance fragment ions containing many hundreds of residues that were undetectable by standard Orbitrap measurements, leading to a doubling in the sequence coverage of triosephosphate isomerase. Thus MS/MS with the detection of individual ions (MS/I2MS) provides a far greater ability to detect high mass fragment ions and exhibits strong complementarity to traditional spectral readout in this, its first application to top-down mass spectrometry.


Assuntos
Proteômica , Espectrometria de Massas em Tandem , Íons
20.
J Am Soc Mass Spectrom ; 31(3): 574-581, 2020 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-31971796

RESUMO

New tools and techniques have dramatically accelerated the field of structural biology over the past several decades. One potent and relatively new technique that is now being utilized by an increasing number of laboratories is the combination of so-called "native" electrospray ionization (ESI) with mass spectrometry (MS) for the characterization of proteins and their noncovalent complexes. However, native ESI-MS produces species at increasingly higher m/z with increasing molecular weight, leading to substantial differences when compared to traditional mass spectrometric approaches using denaturing ESI solutions. Herein, these differences are explored both theoretically and experimentally to understand the role that charge state and isotopic distributions have on signal-to-noise (S/N) as a function of complex molecular weight and how the reduced collisional cross sections of proteins electrosprayed under native solution conditions can lead to improved data quality in image current mass analyzers, such as Orbitrap and FT-ICR. Quantifying ion signal differences under native and denatured conditions revealed enhanced S/N and a more gradual decay in S/N with increasing mass under native conditions. Charge state and isotopic S/N models, supported by experimental results, indicate that analysis of proteins under native conditions at 100 kDa will be 17 times more sensitive than analysis under denatured conditions at the same mass. Higher masses produce even larger sensitivity gains. Furthermore, reduced cross sections under native conditions lead to lower levels of ion decay within an Orbitrap scan event over long transient acquisition times, enabling isotopic resolution of species with molecular weights well in excess of those typically resolved under denatured conditions.


Assuntos
Proteínas/química , Animais , Humanos , Íons/química , Desnaturação Proteica , Espectrometria de Massas por Ionização por Electrospray , Eletricidade Estática
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...